Abc Stored Pressure Type Fire Extinguishers
• Fire Extinguishers Capacities 1 Kg 2 Kg 4 Kg • Minimum period for which throw of jet is maintained. 8 Seconds 13 Seconds 13 Seconds • Maximum period to discharge at least 90% of contents. 12 Seconds 16 Seconds 20 Seconds • Minimum range of jets 2 Meters 2 Meters 2 Meters • Fire Rating 1A, 21B 2A, 34B 3A, 55B • Working Pressure 15KGF/cm² 15KGF/cm² 15KGF/cm² • Hydro pressure 36KGF/cm² 36KGF/cm² 36KGF/cm² • Bursting Pressure 55KGF/cm² 55KGF/cm² 55KGF/cm² • Approvals IS: 15683, CE -
Abc Stored Pressure Type Fire Extinguishers
• Fire Extinguishers Capacities 6 Kg 9 Kg • Minimum period for which throw of jet is maintained. 15 Seconds 15 Seconds • Maximum period to discharge at least 90% of contents. 25 Seconds 30 Seconds • Minimum range of jets 2 Meters 2 Meters • Fire Rating 4A, 89B 6A, 183B • Working Pressure 15KGF/cm² 15KGF/cm² • Hydro pressure 36KGF/cm² 36KGF/cm² • Bursting Pressure 55KGF/cm² 55KGF/cm² • Approvals IS: 15683, CE -
Automatic Modular Fire Extinguisher
• Fire Extinguishers Capacities 2 Kg 5 Kg 10 Kg • Minimum period for which throw of jet is maintained. 8 to 10 Seconds 10 to 15 Seconds 15 to 20 Seconds • Propellent Nitrogen Nitrogen Nitrogen • Minimum range of jets 1 to 1.5 Sq.Meters 3.5 to 4 Sq.Meters 7 to 8 Sq.Meters • Testing Pressure 35 Kgs/cm² 35 Kgs/cm² 35 Kgs/cm² • Working Pressure 7 to 10 Kgs/cm² 7 to 10 Kgs/cm² 7 to 10 Kgs/cm² • Hanging Vertically Above Risk 1.5 Meters 1.5 to 2 Meters 1.75 to 2.25 Meters • Extinguishing Agent Powder/Clean Agent Powder/Clean Agent Powder/Clean Agent • Approvals -
Automatic Modular Fire Extinguisher
• Fire Extinguishers Capacities 15 Kg • Minimum period for which throw of jet is maintained. 18-23 Seconds • Propellent Nitrogen • Minimum range of jets 8 to 10 Sq.Meters • Testing Pressure 35 Kgs/cm² • Working Pressure 7 to 10 Kgs/cm² • Hanging Vertically Above Risk 2 to 3 Meters • Extinguishing Agent Powder/Clean Agent • Approvals -
Bc/abc Squeeze Grip Cartridge Type Fire Extinguishers
• Fire Extinguishers Capacities 4 Kg BC 6 Kg BC 9 Kg BC • Minimum period for which throw of jet is maintained. 15 Seconds 15 Seconds 15 Seconds • Maximum period to discharge at least 90% of contents. 25 Seconds 25 Seconds 30 Seconds • Minimum range of jets 2 Meters 2 Meters 2 Meters • Fire Rating 144 B 183 B 233 B • Working Pressure 15KGF/cm² 15KGF/cm² 15KGF/cm² • Hydro pressure 36 KGF/cm² 36 KGF/cm² 36 KGF/cm² • Bursting Pressure 55 KGF/cm² 55 KGF/cm² 55 KGF/cm² • Approvals IS: 15683 -
Clean Agent Gas Based Fire Extinguishers
• Fire Extinguishers Capacities 2 kg 4 Kg 6 Kg • Minimum period for which throw of jet is maintained. 8 Seconds 13 Seconds 13 Seconds • Maximum period to discharge at least 90% of contents. 15 Seconds 25 Seconds 27 Seconds • Minimum range of jets 2 Meters 2 Meters 2 Meters • Fire Rating 1A, 21B 2A, 34B 2A, 55B • Working Pressure 15KGF/cm² 15KGF/cm² 15KGF/cm² • Hydro pressure 36KGF/cm² 36KGF/cm² 36KGF/cm² • Bursting Pressure 55KGF/cm² 55KGF/cm² 55KGF/cm² • Approvals IS: 15683, CE, GAS: DUPONT® FE36® Clean Agent -
Foam Squeeze Grip Cartridge Type Fire Extinguishers
• Fire Extinguishers Capacities 9 Litres • Minimum period for which throw of jet is maintained. 15 Seconds • Maximum period to discharge at least 90% of contents. 60 Seconds • Minimum range of jets 2 Meters • Fire Rating 4 A, 233 B • Working Pressure 15 KGF/cm² • Hydro pressure 36 KGF/cm² • Bursting Pressure 55 KGF/cm² • Approvals IS: 15683, CE -
Foam Store Pressure Type Fire Extinguishers
• Fire Extinguishers Capacities 9 Litres • Minimum period for which throw of jet is maintained. 15 Seconds • Maximum period to discharge at least 90% of contents. 60 Seconds • Minimum range of jets 2 Meters • Fire Rating 4 A, 233 B • Working Pressure 15 KGF/cm² • Hydro pressure 36 KGF/cm² • Bursting Pressure 55 KGF/cm² • Approvals IS: 15683, CE -
Trolley Mounted Type Co2 Fire Extinguishers
• Fire Extinguishers Capacities 6.5 Kg 9 Kg 22.5 Kg • Minimum period for which throw of jet is maintained. 15 Seconds 15 Seconds 15 Seconds • Maximum period to discharge at least 90% of contents. 30 Seconds 40 Seconds 60 Seconds • Minimum range of jets 2 Meters 2 Meters 2 Meters • Fire Rating 55 B 55 B 89 B • Working Pressure 60KGF/cm² 60KGF/cm² 60KGF/cm² • Hydro pressure 250KGF/cm² 250KGF/cm² 250KGF/cm² • Approvals IS: 15683 -
Trolley Mounted Water Type Fire Extinguishers
• Fire Extinguishers Capacities 45 Ltrs. • Minimum period for which throw of jet is maintained. 30 Sec • Maximum period to discharge at least 90% of contents. 180 Sec • Minimum range of jets 6 Meters • Fire Rating 20 A • Working Pressure 15KGF/cm² • Hydro pressure 36KGF/cm² • Bursting Pressure 55KGF/cm² • Approvals IS: 16018 -
Trolly Mounted Abc Type Fire Extinguisher
• Fire Extinguishers Capacities 4 Kg ABC 6 Kg ABC 9 Kg ABC • Minimum period for which throw of jet is maintained. 13 Seconds 15 Seconds 15 Seconds • Maximum period to discharge at least 90% of contents. 25 Seconds 25 Seconds 30 Seconds • Minimum range of jets 2 Meters 2 Meters 2 Meters • Fire Rating 3A, 55B 4A, 89B 6A, 183B • Working Pressure 15KGF/cm² 15KGF/cm² 15KGF/cm² • Hydro pressure 36 KGF/cm² 36 KGF/cm² 36 KGF/cm² • Bursting Pressure 55 KGF/cm² 55 KGF/cm² 55 KGF/cm² • Approvals IS: 15683 -
Trolly Mounted Foam Type Fire Extinguishers
• Fire Extinguishers Capacities 45 Ltrs. • Minimum period for which throw of jet is maintained. 30 Sec • Maximum period to discharge at least 90% of contents. 180 Sec • Minimum range of jets 6 Meters • Fire Rating 20 A, 233 B • Working Pressure 15KGF/cm² • Hydro pressure 36KGF/cm² • Bursting Pressure 55KGF/cm² • Approvals IS: 16018 -
Trolly Mounted Water & Foam Type Fire Extinguisher
• Fire Extinguishers Capacities 60 Litres (Water Based) 60 Litres (Foam Based) • Minimum period for which throw of jet is maintained. 30 Seconds 30 Seconds • Maximum period to discharge at least 90% of contents. 180 Seconds 180 Seconds • Minimum range of jets 6 Meters 6 Meters • Fire Rating 20A 20A, 233B • Working Pressure 15KGF/cm² 15KGF/cm² • Hydro pressure 36KGF/cm² 36KGF/cm² • Bursting Pressure 55KGF/cm² 55KGF/cm² • Approvals IS: 16018 -
Water Squeeze Grip Cartridge Type Fire Extinguishers
• Fire Extinguishers Capacities 9 Ltrs. • Minimum period for which throw of jet is maintained. 13 Sec • Maximum period to discharge at least 90% of contents. 100 Sec • Minimum range of jets 2 Meters • Fire Rating 3A • Working Pressure 15KGF/cm² • Hydro pressure 36KGF/cm² • Bursting Pressure 55KGF/cm² • Approvals IS: 15683, CE -
Water stored pressure type fire extinguishers
• Fire Extinguishers Capacities 9 Ltrs. • Minimum period for which throw of jet is maintained. 13 Sec • Maximum period to discharge at least 90% of contents. 100 Sec • Minimum range of jets 2 Meters • Fire Rating 3A • Working Pressure 15KGF/cm² • Hydro pressure 36KGF/cm² • Bursting Pressure 55KGF/cm² • Approvals IS: 15683, CE -
Wheel Type / Squeeze Grip Type Co2 Portable Fire Extinguishers
• Fire Extinguishers Capacities 2 kg 3 kg 4.5 kg • Minimum period for which throw of jet is maintained. 8 Seconds 8 Seconds 8 Seconds • Maximum period to discharge at least 90% of contents. 18 Seconds 20 Seconds 25 Seconds • Minimum range of jets 2 Meters 2 Meters 2 Meters • Fire Rating 21 B 34 B 34 B • Working Pressure 60KGF/cm² 60KGF/cm² 60KGF/cm² • Hydro pressure 250KGF/cm² 250KGF/cm² 250KGF/cm² • Approvals IS: 15683