Showing all 16 results

  • ABC STORED PRESSURE TYPE FIRE EXTINGUISHERS

    Abc Stored Pressure Type Fire Extinguishers

    • Fire Extinguishers Capacities 1 Kg 2 Kg 4 Kg
    • Minimum period for which throw of jet is maintained. 8 Seconds 13 Seconds 13 Seconds
    • Maximum period to discharge at least 90% of contents. 12 Seconds 16 Seconds 20 Seconds
    • Minimum range of jets 2 Meters 2 Meters 2 Meters
    • Fire Rating 1A, 21B 2A, 34B 3A, 55B
    • Working Pressure 15KGF/cm² 15KGF/cm² 15KGF/cm²
    • Hydro pressure 36KGF/cm² 36KGF/cm² 36KGF/cm²
    • Bursting Pressure 55KGF/cm² 55KGF/cm² 55KGF/cm²
    • Approvals IS: 15683, CE
  • Abc Stored Pressure

    Abc Stored Pressure Type Fire Extinguishers

    • Fire Extinguishers Capacities 6 Kg 9 Kg
    • Minimum period for which throw of jet is maintained. 15 Seconds 15 Seconds
    • Maximum period to discharge at least 90% of contents. 25 Seconds 30 Seconds
    • Minimum range of jets 2 Meters 2 Meters
    • Fire Rating 4A, 89B 6A, 183B
    • Working Pressure 15KGF/cm² 15KGF/cm²
    • Hydro pressure 36KGF/cm² 36KGF/cm²
    • Bursting Pressure 55KGF/cm² 55KGF/cm²
    • Approvals IS: 15683, CE
  • AUTOMATIC MODULAR FIRE EXTINGUISHER

    Automatic Modular Fire Extinguisher

    • Fire Extinguishers Capacities 2 Kg 5 Kg 10 Kg
    • Minimum period for which throw of jet is maintained. 8 to 10 Seconds 10 to 15 Seconds 15 to 20 Seconds
    • Propellent Nitrogen Nitrogen Nitrogen
    • Minimum range of jets 1 to 1.5 Sq.Meters 3.5 to 4 Sq.Meters 7 to 8 Sq.Meters
    • Testing Pressure 35 Kgs/cm² 35 Kgs/cm² 35 Kgs/cm²
    • Working Pressure 7 to 10 Kgs/cm² 7 to 10 Kgs/cm² 7 to 10 Kgs/cm²
    • Hanging Vertically Above Risk 1.5 Meters 1.5 to 2 Meters 1.75 to 2.25 Meters
    • Extinguishing Agent Powder/Clean Agent Powder/Clean Agent Powder/Clean Agent
    • Approvals
  • Placeholder

    Automatic Modular Fire Extinguisher

    • Fire Extinguishers Capacities 15 Kg
    • Minimum period for which throw of jet is maintained. 18-23 Seconds
    • Propellent Nitrogen
    • Minimum range of jets 8 to 10 Sq.Meters
    • Testing Pressure 35 Kgs/cm²
    • Working Pressure 7 to 10 Kgs/cm²
    • Hanging Vertically Above Risk 2 to 3 Meters
    • Extinguishing Agent Powder/Clean Agent
    • Approvals
  • BC/ABC SQUEEZE GRIP CARTRIDGE TYPE FIRE EXTINGUISHERS

    Bc/abc Squeeze Grip Cartridge Type Fire Extinguishers

    • Fire Extinguishers Capacities 4 Kg BC 6 Kg BC 9 Kg BC
    • Minimum period for which throw of jet is maintained. 15 Seconds 15 Seconds 15 Seconds
    • Maximum period to discharge at least 90% of contents. 25 Seconds 25 Seconds 30 Seconds
    • Minimum range of jets 2 Meters 2 Meters 2 Meters
    • Fire Rating 144 B 183 B 233 B
    • Working Pressure 15KGF/cm² 15KGF/cm² 15KGF/cm²
    • Hydro pressure 36 KGF/cm² 36 KGF/cm² 36 KGF/cm²
    • Bursting Pressure 55 KGF/cm² 55 KGF/cm² 55 KGF/cm²
    • Approvals IS: 15683
  • Clean Agent Gas Based Fire Extinguishers

    Clean Agent Gas Based Fire Extinguishers

    • Fire Extinguishers Capacities 2 kg 4 Kg 6 Kg
    • Minimum period for which throw of jet is maintained. 8 Seconds 13 Seconds 13 Seconds
    • Maximum period to discharge at least 90% of contents. 15 Seconds 25 Seconds 27 Seconds
    • Minimum range of jets 2 Meters 2 Meters 2 Meters
    • Fire Rating 1A, 21B 2A, 34B 2A, 55B
    • Working Pressure 15KGF/cm² 15KGF/cm² 15KGF/cm²
    • Hydro pressure 36KGF/cm² 36KGF/cm² 36KGF/cm²
    • Bursting Pressure 55KGF/cm² 55KGF/cm² 55KGF/cm²
    • Approvals IS: 15683, CE, GAS: DUPONT® FE36® Clean Agent
  • FOAM SQUEEZE GRIP CARTRIDGE TYPE FIRE EXTINGUISHERS

    Foam Squeeze Grip Cartridge Type Fire Extinguishers

    • Fire Extinguishers Capacities 9 Litres
    • Minimum period for which throw of jet is maintained. 15 Seconds
    • Maximum period to discharge at least 90% of contents. 60 Seconds
    • Minimum range of jets 2 Meters
    • Fire Rating 4 A, 233 B
    • Working Pressure 15 KGF/cm²
    • Hydro pressure 36 KGF/cm²
    • Bursting Pressure 55 KGF/cm²
    • Approvals IS: 15683, CE
  • FOAM STORE PRESSURE TYPE FIRE EXTINGUISHERS

    Foam Store Pressure Type Fire Extinguishers

    • Fire Extinguishers Capacities 9 Litres
    • Minimum period for which throw of jet is maintained. 15 Seconds
    • Maximum period to discharge at least 90% of contents. 60 Seconds
    • Minimum range of jets 2 Meters
    • Fire Rating 4 A, 233 B
    • Working Pressure 15 KGF/cm²
    • Hydro pressure 36 KGF/cm²
    • Bursting Pressure 55 KGF/cm²
    • Approvals IS: 15683, CE
  • Trolley Mounted Type Co2

    Trolley Mounted Type Co2 Fire Extinguishers

    • Fire Extinguishers Capacities 6.5 Kg 9 Kg 22.5 Kg
    • Minimum period for which throw of jet is maintained. 15 Seconds 15 Seconds 15 Seconds
    • Maximum period to discharge at least 90% of contents. 30 Seconds 40 Seconds 60 Seconds
    • Minimum range of jets 2 Meters 2 Meters 2 Meters
    • Fire Rating 55 B 55 B 89 B
    • Working Pressure 60KGF/cm² 60KGF/cm² 60KGF/cm²
    • Hydro pressure 250KGF/cm² 250KGF/cm² 250KGF/cm²
    • Approvals IS: 15683
  • water-based-trolley-mounted

    Trolley Mounted Water Type Fire Extinguishers

    • Fire Extinguishers Capacities 45 Ltrs.
    • Minimum period for which throw of jet is maintained. 30 Sec
    • Maximum period to discharge at least 90% of contents. 180 Sec
    • Minimum range of jets 6 Meters
    • Fire Rating 20 A
    • Working Pressure 15KGF/cm²
    • Hydro pressure 36KGF/cm²
    • Bursting Pressure 55KGF/cm²
    • Approvals IS: 16018
  • BC/ABC SQUEEZE GRIP CARTRIDGE TYPE FIRE EXTINGUISHERS

    Trolly Mounted Abc Type Fire Extinguisher

    • Fire Extinguishers Capacities 4 Kg ABC 6 Kg ABC 9 Kg ABC
    • Minimum period for which throw of jet is maintained. 13 Seconds 15 Seconds 15 Seconds
    • Maximum period to discharge at least 90% of contents. 25 Seconds 25 Seconds 30 Seconds
    • Minimum range of jets 2 Meters 2 Meters 2 Meters
    • Fire Rating 3A, 55B 4A, 89B 6A, 183B
    • Working Pressure 15KGF/cm² 15KGF/cm² 15KGF/cm²
    • Hydro pressure 36 KGF/cm² 36 KGF/cm² 36 KGF/cm²
    • Bursting Pressure 55 KGF/cm² 55 KGF/cm² 55 KGF/cm²
    • Approvals IS: 15683
  • FOAM SQUEEZE GRIP CARTRIDGE TYPE FIRE EXTINGUISHERS

    Trolly Mounted Foam Type Fire Extinguishers

    • Fire Extinguishers Capacities 45 Ltrs.
    • Minimum period for which throw of jet is maintained. 30 Sec
    • Maximum period to discharge at least 90% of contents. 180 Sec
    • Minimum range of jets 6 Meters
    • Fire Rating 20 A, 233 B
    • Working Pressure 15KGF/cm²
    • Hydro pressure 36KGF/cm²
    • Bursting Pressure 55KGF/cm²
    • Approvals IS: 16018
  • TROLLY MOUNTED WATER & FOAM TYPE FIRE EXTINGUISHER

    Trolly Mounted Water & Foam Type Fire Extinguisher

    • Fire Extinguishers Capacities 60 Litres (Water Based) 60 Litres (Foam Based)
    • Minimum period for which throw of jet is maintained. 30 Seconds 30 Seconds
    • Maximum period to discharge at least 90% of contents. 180 Seconds 180 Seconds
    • Minimum range of jets 6 Meters 6 Meters
    • Fire Rating 20A 20A, 233B
    • Working Pressure 15KGF/cm² 15KGF/cm²
    • Hydro pressure 36KGF/cm² 36KGF/cm²
    • Bursting Pressure 55KGF/cm² 55KGF/cm²
    • Approvals IS: 16018
  • WATER SQUEEZE GRIP CARTRIDGE TYPE FIRE EXTINGUISHERS

    Water Squeeze Grip Cartridge Type Fire Extinguishers

    • Fire Extinguishers Capacities 9 Ltrs.
    • Minimum period for which throw of jet is maintained. 13 Sec
    • Maximum period to discharge at least 90% of contents. 100 Sec
    • Minimum range of jets 2 Meters
    • Fire Rating 3A
    • Working Pressure 15KGF/cm²
    • Hydro pressure 36KGF/cm²
    • Bursting Pressure 55KGF/cm²
    • Approvals IS: 15683, CE
  • WATER STORED PRESSURE TYPE FIRE EXTINGUISHER

    Water stored pressure type fire extinguishers

    • Fire Extinguishers Capacities 9 Ltrs.
    • Minimum period for which throw of jet is maintained. 13 Sec
    • Maximum period to discharge at least 90% of contents. 100 Sec
    • Minimum range of jets 2 Meters
    • Fire Rating 3A
    • Working Pressure 15KGF/cm²
    • Hydro pressure 36KGF/cm²
    • Bursting Pressure 55KGF/cm²
    • Approvals IS: 15683, CE
  • WHEEL TYPE / SQUEEZE GRIP TYPE CO2 PORTABLE FIRE EXTINGUISHERS

    Wheel Type / Squeeze Grip Type Co2 Portable Fire Extinguishers

    • Fire Extinguishers Capacities 2 kg 3 kg 4.5 kg
    • Minimum period for which throw of jet is maintained. 8 Seconds 8 Seconds 8 Seconds
    • Maximum period to discharge at least 90% of contents. 18 Seconds 20 Seconds 25 Seconds
    • Minimum range of jets 2 Meters 2 Meters 2 Meters
    • Fire Rating 21 B 34 B 34 B
    • Working Pressure 60KGF/cm² 60KGF/cm² 60KGF/cm²
    • Hydro pressure 250KGF/cm² 250KGF/cm² 250KGF/cm²
    • Approvals IS: 15683